ATMOSPHERIC AGENTS

GENERAL USE


FORMULA
REFERENCE

SEE

Hardness
IRHD
(2)

Classification
following norm
NFL
EN

Fire
Grade (3)

REMARKS

(specific characteristics, use restriction)

DESIGNATION

Working temperature :
(1)

Through service:

Peak temp.S

ATMOSPHERIC
AGENTS

Thermal
Insulation

Contact with acrylic
plastices  : window

-40°C
to
+100°C

-40°C
to
+120°C

4 NE 1307
6 NE 1300

40
60

       

b2

Resistance to different petrol fluids.
Mediocre resistance to fuels and petrol fluids with low or middle aniline point in case of full immersion
. hot air circuits





. access door

. canopies

. various profiles

-40°C
to
+100°C

-40°C
to
+120°C

3 NE 1010
4 NE 1011
5 NE 1012
6 NE 1013
7 NE 1014
8 NE 1015

30
40
50
60
70
80

31 B3
31 B4
31 B5
31 B6
31 B7
31 B8

b2
b2
b2
b2
b2
b2

-55°C
to
+100°C

-55°C
to
+140°C

6 EP 1180

55

42 B6

X

Resistance to  projections of   ester phosphoric fluids

-55°C
to
+125°C

-55°C
to
+160°C

5 EP 1285
6 EP 1286
7 EP 1287
8 EP 1288
9 EP 1289

50
60
70
80
90

NF EN 2428
NF EN 2429
NF EN 2430
NF EN 2431
NF EN 2432

X
X
X
X
X

Resistance to extremly high temperatures and good resistance to the creeping

-75°C
to
+225°C

-75°C
to
+250°C

4 SL 1305
5 SL 1294

40
50

        

b2
b2

Resistance to extremly high temperatures and good resistance to the creeping

-55°C
to
+225°C

-55°C
to
+260°C

50D4
50D5
50D6
50D7
50D8

40
50
60
70
80

50 D4
EN 2259
EN 2260
EN 2261
50 D8

b2
b2
b2
b2
b2

Resistance to extremly high temperatures and good resistance to the creeping

-70°C

to

+200°C

-70°C

to

+225°C

53D5

50

53 D5

b

Fire holding. High resistance to the tearing.

52D5

50

EN 2262

b2

High resistance to the tearing.
 

-55°C
to
+250°C

-55°C
to
+300°C

54D4
54D5
54D6
54D7

40
50
60
70

54 D4
54 D5
54 D6
54 D7

b2
b2
b2

High resistance to the creeping.
  Cellular materials

-60°C
to
+200°C

-60°C
to
+250°C

4 SL 1179

Densité
0,40
0,25

    

b2
b2

Fabrication of molded sheets and profiles with easy geometry (in broken whiter)
OXYGEN

-20°C
to
+200°C

-20°C
to
+100°C

8 NE 1309

80

     

X

Only for oxygen use

-40°C
to
+225°C

-40°C
to
+260°C

8 SL 1301

80

          Low inflammability in presence of oxygen

-20°C
to
+200°C

-20°C
to
+220°C

7 DF 1304

80

          High resistance to the creeping.
Good tightness
ELECTRICAL
INSULATION

-30°C
to
+100°C

-30°C
to
+120°C

7 NE 1297

70

32 A7

Dielectric use.

NOTES :

  1. Working temperatures depend on numerous factors and are given for information only. Please contact us.
  2. Normalised testing following  NFT 46003. Hardness' found on parts can differ of given values because of the shape and the difficulty to test on the part following the norm.
  3. b and b² : test following norm FAR 25, amendment 32, paragraph 25853.
    The sign X means the formulae has not been tested or is not concerned by this testing.
  4. SKYDROL is a trade-mark of MONSANTO company.